Sie sind vermutlich noch nicht im Forum angemeldet - Klicken Sie hier um sich kostenlos anzumelden Impressum 
Sie können sich hier anmelden
Dieses Thema hat 7 Antworten
und wurde 534 mal aufgerufen
 Probleme
simybrigy Offline



Beiträge: 75

20.01.2010 15:21
Lotstation profi LS1000 Zitat · Antworten

Hello everyone.
I have a problem with my welder.
I used it a few times cosservato always good.
The problem is that last night it worked perfectly, and this morning began to fail.
the temperature of the pen does not rise, I checked the cables and they are all ok.
may depend on what if the temperature stays at 25 ° C, although INPOST from 150 ° C to 450 ° C.
May have burned since yesterday I took him to the maximum temperature?
I hope someone can help me.
Thank you to copy.
Yours sincerely Simon.

Hallo an alle.
Ich habe ein Problem mit meinem Schweißer.
Ich habe es ein paar Mal cosservato immer gut.
Das Problem ist, dass gestern Abend es funktionierte perfekt, und heute morgen begann zu scheitern.
die Temperatur der Stift nicht steigen, überprüfte ich die Kabel, und sie sind alle in Ordnung.
kann davon abhängen, was bleibt, wenn die Temperatur bei 25 ° C, obwohl INPOST von 150 ° C bis 450 ° C.
Mai gebrannt haben seit gestern nahm ich ihn auf die maximale Temperatur?
Ich hoffe jemand kann mir helfen.
Wir danken Ihnen, zu kopieren.
Mit freundlichen Grüßen Simon.


Sven Löffler Offline

Admin


Beiträge: 3.713

20.01.2010 15:42
#2 RE: Lotstation profi LS1000 Zitat · Antworten

Hi Simon,

have you checked the fuse ? Maybe at the backstide of the station.


simybrigy Offline



Beiträge: 75

20.01.2010 16:03
#3 RE: Lotstation profi LS1000 Zitat · Antworten

Zitat von Sven Löffler
Hi Simon,

have you checked the fuse ? Maybe at the backstide of the station.



Dear Sven excuse me much but I did not understand what you mean?


Sven Löffler Offline

Admin


Beiträge: 3.713

20.01.2010 16:11
#4 RE: Lotstation profi LS1000 Zitat · Antworten

What happen, when you switch the main power on ? Works the display ?


Bernhard Offline




Beiträge: 1.152

20.01.2010 16:21
#5 RE: Lotstation profi LS1000 Zitat · Antworten

Hello Simon,

if the Display works,

i believ, the Heat-Element is defect.

You should can mess between two Connectors a Resistance of ca.8 OHMS.

http://www.radiostore.de/shop/Loettechni...-937::2043.html

Best Regards
Bernhard


simybrigy Offline



Beiträge: 75

20.01.2010 16:54
#6 RE: Lotstation profi LS1000 Zitat · Antworten

Yes the display is working properly.
So you think you burned?
http://www.radiostore.de/shop/Loettechni...-937::2043.html
Why has reached 450 ° C or because it is defective?
was the first time I wore at that temperature I have used more than 5 times.
Thanks for the help I hope to have this fixed soon.
Do you know if this store has paypal?
Regards Simon.


Bernhard Offline




Beiträge: 1.152

20.01.2010 17:05
#7 RE: Lotstation profi LS1000 Zitat · Antworten

if it's reaching 450°C is the Temperatur-Sensor demaged.

I have found one, but this Shop accepts only Master or Visa-Card

http://www.radiostore.de/shop/Loettechni...S-1000::58.html

Regards
Bernhard


simybrigy Offline



Beiträge: 75

20.01.2010 17:11
#8 RE: Lotstation profi LS1000 Zitat · Antworten

Zitat von Bernhard
if it's reaching 450°C is the Temperatur-Sensor demaged.

I have found one, but this Shop accepts only Master or Visa-Card

http://www.radiostore.de/shop/Loettechni...S-1000::58.html

Regards
Bernhard



Thank you very much Bernhard.
Regards Simon.


 Sprung  

disconnected Mikromodell-Chat Mitglieder Online 4
Xobor Xobor Community Software